KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Jual Multi Function Testers KEW 6016

 

Multi Function Testers

KEW 6016

KEW 6016
CE AutoDischarge ATT
 
Continuity Measurement
Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.

Insulation Measurement
Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.

Loop Impedance Measurement
A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's.
A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.

PSC / PFC Measurement
The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.

RCD Measurement
The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).

Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application.

Earth Measurement
Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.

Phase rotation
KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.

Voltage Measurement
In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.

Continuity
Range 20/200/2000Ω (Auto-ranging)
 Open circuit
voltage (DC)
5V±20% (*1)
Short circuit
current
Greater than 200mA
Accuracy  ±0.1Ω (0 - 0.19Ω)
±2%rdg+8dgt (0.2 - 2000Ω) 
Insulation Resistance
Range 20/200MΩ
(Auto-ranging)
20/200/2000MΩ (Auto-ranging)
Open circuit
voltage (DC)
250V+25% -0% 500V+25% -0% 1000V+20% -0%
Rated current 1mA or greater
@ 250kΩ 
1mA or greater
@ 500kΩ
1mA or greater
@ 1MΩ
Accuracy ±2%rdg+6dgt
(0 - 19.99MΩ)
±5%rdg+6dgt
(20 - 200MΩ)
±2%rdg+6dgt (0 - 199.9MΩ)
±5%rdg+6dgt (200 - 2000MΩ)
Loop Impedance
Function L-PE L-PE (ATT) L-N / L-L
Rated Voltage 100 - 260V 50/60Hz L-N: 100 - 300V
L-L: 300 - 500V
50/60Hz
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*2)
20Ω: 6A/20ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s
20Ω: 6A/20ms
Range 20/200/2000Ω
(Auto-ranging)
20/200/2000Ω
(Auto-ranging)
(L-N < 20Ω)
20Ω
Accuracy ±3%rdg+4dgt(*3)
±3%rdg+8dgt(*4)
±3%rdg+6dgt (*3)
±3%rdg+8dgt(*4)
±3%rdg+4dgt (*3)
±3%rdg+8dgt(*4)  
PSC (L-N / L-L) / PFC (L-PE)
Function PSC PFC PFC (ATT)
Rated Voltage 100 - 500V 50/60Hz 100 - 260V 50/60Hz  
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*5)
6A/20ms 6A/20ms
2A/20ms
15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s 
 Range 2000A/20kA Auto-Ranging
Accuracy PSC / PFC accuracy is derived from measured loop impedance
specification and measured voltage specification
RCD
Function X1/2 X1 X5 Ramp Auto
Trip current
setting
10/30/100/300/
500/1000mA
10/30/
100mA   
10/30/
100/300/
500mA
Depending on the
accuracy at each
function.
Measurement sequence:
X1/2 0°→X1/2 180°
→X1 0°→X1 180°
→X5 0°→X5 180°
Measurements with
x5 are not carried out
for RCDs with
nominal current of
100mA or more.
Trip current
Duration
2000ms G: 550ms
S: 1000ms
410ms Goes up by
10% from
20% to
110%
G:300ms/
S:500ms
X10 times
Rated Voltage 230V+10%-15% 50/60Hz
Accuracy AC Type:
-8% - -2%
A Type:
-10% - 0%
AC Type: +2% - +8%
A Type: 0% - +10%
AC Type: ±4%
A Type: ±10%
Trip time: ±1%rdg+3dgt
RCD (Uc)
Function UC
Rated Voltage 230V+10% - 15% 50/60Hz
Range 100.0V
Test current ≤ 1/2IΔn (max150mA)
Accuracy +5% - +15%rdg, ±8dgt
Earth
Range 20/200/2000Ω Auto-Ranging
Accuracy 20Ω: ±3%rdg+0.1Ω
200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)
Phase Rotation
Rated Voltage 50-500V 50/60Hz
Remarks Correct phase sequence: are displayed "1.2.3" and  recycle mark
Reversed phase sequence: are displayed "3.2.1" and  recycle mark
Volts
Function Volts Frequency
Rated Voltage 25 - 500V, 45 - 65Hz
Measuring range  25 - 500V 45 - 65Hz
Accuracy ±2%rdg+4dgt ±0.5%rdg+2dgt
Applicable standards IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031,
IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)
Power source LR6 X 8
Dimensions 136(L) X 235(W) X 114(D)mm
Weight 1350g (including batteries.)
Included Accessories 7188A (Distribution board fuse test lead set)
7196A (Test leads with remote control switch)
7218A (Power cord [EU]) (*6)
7228A (Earth resistance test leads)
8032 (Auxiliary earth spikes)
8212-USB (USB adaptor with KEW Report (Software))
9142 (Carrying case)
9121 (Shoulder strap)
Cord case, Buckle, Battery, Instruction manual
Optional Accessories 8212-RS232C (RS232C adaptor with KEW Report (Software))

 

Jual Multi Function Testers MODEL 6011A

 

Multi Function Testers

MODEL 6011A

MODEL 6011A
CE
 
• Complies with IEC 61557
• Designed to IP 54 Rating
• Live circuit and wiring connection check LED's
• Triple ranges insulation tests at 250, 500 and 1000V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
• Phase angle selection on RCD ranges
• Polarity switch for continuity tests
• Auto-null facility for continuity tests
• Earth probe for loop impedance testing on extraneous metalwork
• Contact Voltage Reading
• Test of a large kind of RCD's: Standard, Selective, AC and A
(DC sensitive breakers)
 
Continuity Testing
Measuring Ranges 20/200/2000Ω (Autoranging)
Open Circuit Voltage >6V
Short Circuit Current >200mA DC
Accuracy ±(1.5%rdg+3dgt)
Insulation Testing
Measuring Ranges 20/200MΩ (Autoranging)
Test Voltage 250V 500V 1000V DC
Output Voltage on Open Circuit 250V+40%-0%
500V+30%-0%
1000V+20%-0%
Rated Current > 1mA
Accuracy ±(1.5%rdg+3dgt)
Loop Impedance Testing
Rated Voltage 230V AC +10%-15% [50Hz]
Voltage Measuring Range 100 - 250V AC [50Hz]
Impedance Ranges 20/200/2000Ω
Nominal Test Current 25A (20Ω range) 15mA (200Ω range) 15mA (2000Ω range)
Accuracy 20Ω range ±(3%rdg +4dgt)
200Ω range ±(3%rdg +8dgt)
2000Ω range ±(3%rdg +4dgt)
PSC Testing
Rated Voltage 230V AC +10%-15% [50Hz]
PSC Ranges 200A (15mA Test Current)
2000A (25A Test Current)
20kA (25A Test Current)
Accuracy PSC accuracy derived from measured loop impedance specification
and measured voltage specification
RCD Testing
Rated Voltage 230V AC +10%-15% [50Hz]
Trip Current Settings RCD × 1/2 : 10,30,100,300,500,1000mA
RCD × 1 : 10,30,100,300,500,1000mA
RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A)
Trip Current Duration RCD × 1/2 × 1: 2000ms
RCD fast: 50ms
Accuracy Trip current +10%-0% of test current at 230V
Trip time ±(1%rdg + 3dgt)
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557
Power source LR6 (1.5V) × 8
Dimensions 130(L) × 183(W) × 100(D)mm
Weight 1100g approx.
Included Accessories *KAPM10
(Molded plug test leads for loop and RCD testing at sockets)
7122B (Test leads)
7132A (External earth probe)
Pouch for Test Leads
9121 (Shoulder Strap)
Battery LR6 (1.5V) × 8
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)

 

Jual Multi Function Testers KEW 6010B

 

Multi Function Testers

KEW 6010B

KEW 6010B
CE
 
• Continuity:20/200Ω 200mA Test Current
• Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current
• Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
• RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
• Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers)
• Uc(Contact Voltage): 100V
• Designed to IEC 61010-1, IEC 61557
• Data Memory:300 measured results
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.
 
Continuity Testing
Measuring Range 20/200Ω (Auto-Ranging)
Open Circuit Voltage > 6V
Short Circuit Current > 200mA
Accuracy ±(3%rdg + 3dgt)
Insulation Resistance Testing
Measuring Range 20/200MΩ (Auto-Ranging)
Test Voltage 500/1000V
Open Circuit Voltage +20% - 0%
Rated Current > 1mA
Accuracy ± (3%rdg + 3dgt)
Loop Impedance Testing
Impedance Range 20/2000Ω
Rated Voltage 230V + 10% - 15%(50Hz)
Normal Test Current 20Ω:25A/10ms
2000Ω:15mA/350ms max.
Accuracy ±(3%rdg + 8dgt)
RCD Testing
Test Current
(Test Current Duration)
x1/2, x1 10, 30, 100, 300, 500mA (2000ms)
Fast 150mA (50ms)
DC 10, 30, 100, 300mA (2000ms), 500mA (200ms)
Auto Ramp Goes up by 10% from 20% to 110% of IΔn. 300ms×10
Rated Voltage 230V + 10% - 15% 50Hz
AccuracyTest Current x1/2: -8%-2%
x1, FAST: +2%+8%
DC: ±10%
Auto Ramp: ±4%
Trip Time ±(1%rdg + 3dgt)
Uc Testing
Measuring Range 100V
Rated Voltage 230V + 10% - 15% (50Hz)
Test Current 5mA at IΔn = 10mA
15mA at IΔn = 30/100mA
150mA at IΔn = 300/500mA
Accuracy +5%+15%rdg, ±8dgt
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
Power source R6 or LR6 × 8
Dimensions 175(L) × 115(W) × 86(D)mm
Weight 840g approx.
Included Accessories 7122B (Test leads)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)
8212-RS232C (RS232C adaptor with "KEW Report (Software)")
8212-USB (USB adaptor with "KEW Report (Software)")

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 14 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...