Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Jual Multi Function Testers MODEL 6010A

 

Multi Function Testers

MODEL 6010A

MODEL 6010A
CE
 
Continuity and Insulation Testing
• Live circuit warning LED:
Immediate illumination of a warning lamp if the circuit under test is live
• Auto Discharge:
Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
• Integral overload protection on internal continuity and insulation test circuitry
• Autoranging
• 500V DC test voltage for insulation tests
• 200mA short circuit current on continuity ranges

Loop and RCD Testing
• Wiring connection check LED’s:
Immediate indication if wiring of circuit under test is correct
• Overheat Protection:
Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
• Supply Voltage Indication:
Can display supply voltage value in loop impedance mode
• Low Current Loop Impedance Test:
Short duration low test current will prevent tripping of many passive RCDs
• Auto Data Hold:
Retains displayed reading for set period following test
• Phase Angle Selection:
Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs
 
Continuity Testing
Measuring Ranges 0 - 19.99 and 10.0 - 199.9Ω (2 auto ranges)
Open Circuit Voltage > 4V (as per IEC 364)
Short Circuit Current > 200mA DC (as per IEC 364)
Accuracy ±(3% + 3dgt)
Loop Impedance Testing
Rated Voltage 230V AC +10%-15% (50Hz)
Voltage Measuring Range 100-250V AC (50Hz)
Impedance Range
Nominal Test Current
20/2000Ω
25A (20Ω range) 15mA (2000Ω range)
Test Period 1/2 cycle (10ms)
Accuracy 20Ω range : ±(3% + 8dgt)   2000Ω range : ±(3% + 8dgt)
Insulation Testing
Measuring Ranges 0 - 19.99 and 10.0 - 199.9MΩ (2 auto ranges)
Test Voltage 500V DC
Output Voltage on
Open Circuit
570V DC±6%
Rated Current > 1mA (as per IEC 364)
Accuracy ± (3% + 3dgt)
RCD Testing
Rated Voltage 230V AC +10%-15% (50Hz)
Trip Current Settings RCD × 1/2: 5, 15, 50, 150, 250mA
RCD × 1: 10, 30, 100, 300, 500mA
Trip Current Duration RCD × 1/2 × 1: 2000ms
Fast Trip 150mA
Accuracy Trip current ±3% of test current at 230V.
Trip time ±(3% + 3dgt)
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557
Power source R6 (AA) (1.5V) × 8
Dimensions 175(L) × 115(W) × 86(D)mm
Weight 780g approx.
Included Accessories 7122B (Test leads)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
R6 (AA) × 8
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)

 

Jual Multi Function Testers Kyoritsu

Multi Function Testers

  • MODEL 6010A

    MODEL 6010A

    Continuity and Insulation Testing
    • Live circuit warning LED:
    Immediate illumination of a warning lamp if the circuit under test is live
    • Auto Discharge:
    Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
    • Integral overload protection on internal continuity and insulation test circuitry
    • Autoranging
    • 500V DC test voltage for insulation tests
    • 200mA short circuit current on continuity ranges

    Loop and RCD Testing
    • Wiring connection check LED's:
    Immediate indication if wiring of circuit under test is correct
    • Overheat Protection:
    Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
    • Supply Voltage Indication:
    Can display supply voltage value in loop impedance mode
    • Low Current Loop Impedance Test:
    Short duration low test current will prevent tripping of many passive RCDs
    • Auto Data Hold:
    Retains displayed reading for set period following test
    • Phase Angle Selection:
    Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs

    • KEW 6010B

      KEW 6010B

      • Continuity: 20/200Ω, 200mA Test Current
      • Insulation: 500/1000V, 20/200MΩ, 1mA Rated Test Current
      • Loop Impedance: 20/2000Ω, 15mA Test Current at 2000Ω (No RCD Trip)
      • RCD: 10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
      • Test of a large kind of RCD's:
      Standard, Selective, AC and A (DC sensitive breakers)
      • Uc (Contact Voltage): 100V
      • Designed to IEC 61010-1, IEC 61557
      • Data Memory: 300 measured results
      • The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

      • MODEL 6011A

        MODEL 6011A

        • Complies with IEC 61557
        • Designed to IP 54 Rating
        • Live circuit and wiring connection check LED's
        • Triple ranges insulation tests at 250, 500 and 1000V
        • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range (No RCD Trip)
        • Phase angle selection on RCD ranges
        • Polarity switch for continuity tests
        • Auto-null facility for continuity tests
        • Earth probe for loop impedance testing on extraneous metalwork
        • Contact Voltage Reading
        • Test of a large kind of RCD's:
        Standard, Selective, AC and A (DC sensitive breakers)

        • KEW 6016

          KEW 6016

          The KEW 6016 Multi-Function tester performs 10 functions
          in one instrument.

          • Continuity tester
          • Insulation resistance tester
          • Loop impedance tester
          • PSC tester
          • PFC tester
          • RCD tester
          • Earth tester
          • Phase rotation tester
          • Voltage measurement
          • Frequency measurement

          • MODEL 6018

            MODEL 6018

            • Designed to meet IEC 61010-1 CAT III 600V
            • Test leads with remote control switch.
            (For insulation&Simplified Earth Test)
            • Back light function.
            • Color coded scales and range switch position for easy reading.
            • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
            • Can be hung around the neck for both hand’s operation.

PV Insulation Earth Tester

KEW 6024PV

KEW 6024PVNEW

• Correct measuring for Insulation resistance even if the panel is under generating power
• Waterproof design: Can measure under the bad weather condition
• Memory function up to 1000 data
• Luminescence button and Backlight

  • Backlight USB AutoPowerOff

Jual

Power Quality Analyzer

KEW 6315NEW

KEW 6315
CE
 
• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
  • TRUE RMS USB Bluetooth External
  • Simultaneous Power & Power quality measurements
    • Power/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch) 
  • Helpful support functions
    • Quick Start Guide, Wiring check and Sensor detection for easy and reliable measurement
  • Measurement with high accuracy
    • Guaranteed accuracy:±0.3%rdg (energy),±0.2%rdg (voltage/ current)
      Complies with the International Standard IEC 61000-4-30 Class S and the European Standard EN50160
  • Remote monitoring on PC and Android device
    • Remote checking of measurement in real-time is possible via Bluetooth communication.
    • Recorded data can be saved in the supplied SD card.
    • EN50160 report can be generated after survey by PC software.
  • Various Clamp Current Sensors
    • Various types of clamp and flexible sensors are available:
      from 1000mA Range up to 3000A Range and Earth leakage measurements
    • Energy consumption check on site
      Trend and demand graphs for easy recognition.
      TFT color display with high resolution.
  • IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

Free Android software "KEW smart 6315" is available on "Google Play Store"

•Supporting Android ver. 2.2 - 4.4
•WVGA (800 × 480) resolution or higher

Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

Power Quality Analyzer

Wiring connections 1P2W, 1P3W, 3P3W, 3P4W
Measurements and parameters Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),
Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),
Capacitance calculation for PF correction unit, Flicker
Voltage (RMS)  
 Range 600.0 / 1000V
Accuracy ±0.2%rdg±0.2%f.s. (sine wave, 40 - 70Hz)
Allowable input 1 - 120% of each range (rms). 200% of each range (peak)
Display range 0.15 - 130% of each range
Crest factor 3 or less
Sampling speed of Voltage transient 24µs
Current (RMS)  
 Range 8128 ( 50A type ) : 5 / 50A / AUTO
8127 ( 100A type ) : 10 / 100A / AUTO
8126 ( 200A type ) : 20 / 200A / AUTO
8125 ( 500A type ) : 50 / 500A / AUTO
8124/8130 ( 1000A type ) : 100 / 1000A / AUTO
8146/8147/8148 ( 10A type ) : 1 / 10A / AUTO
8129 ( 3000A type ) : 300 / 1000 / 3000
Accuracy ±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz)
Allowable input 1 - 110% of each range (rms). 200% of each range (peak)
Display range 0.15 - 130% of each range
Crest factor 3 or less
Active power  
 Accuracy ±0.3%rdg±0.2%f.s. + accuracy of clamp sensor
(power factor 1, sine wave, 40 - 70Hz)
Influence of power factor ±1.0%rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range 40 - 70Hz
Power supply (AC Line) AC100 - 240V / 50 - 60Hz / 7VA max
Power supply (DC battery) Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)
Internal memory FLASH memory (4MB)
PC card interface SD card (2GB)
PC communication interface USB Ver2.0, Bluetooth Ver2.1 + EDR Class2
Display 320 × 240 (RGB) Pixel, 3.5inch color TFT display
Display update period 1 sec

 

General

Applicable standards IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2
IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160
IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7
Temperature and humidity range 23±5ºC, less than 85% RH (without condensation)
Operating temperature & humidity range 0 - +45ºC, less than 85% RH (without condensation)
Storage temperature & humidity range -20 - +60ºC, less than 85% RH (without condensation)
Power supply (AC Line) AC100 - 240V / 50 - 60Hz / 7VA max
Power supply (DC battery) Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)
Dimensions 175(L) × 120(W) × 68(D) mm
Weight Approx. 900g
Included Accessories 7141B (Voltage test lead)
7170 (Power cord)
7219 (USB cable)
8326-02 (SD card 2GB)
9125 (Carrying case for KEW 6315)
9135 (Carrying case for KEW 6315-03)
Input terminal plate × 6, KEW Windows for KEW 6315 (software),
Quick manual, Alkaline size AA battery (LR6) × 6
Optional Accessories 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)
8129, 8130 (Flexible clamp sensor)
8146, 8147, 8148 (Leakage and Load current clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetci carrying case)

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 28 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...