Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Jual Earth Clamp Testers KEW 4202

 

Earth Clamp Testers

KEW 4202

KEW 4202
CE
Various useful functions are available on Android devices using Bluetooth communication
• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
• Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset value

Earth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments
  • TRUE RMS φ32 Backlight Bluetooth

Free Android software "KEW smart 4202"
is available on "Google Play Store"(*)

<System requirement>
• Supporting Android ver. 2.2 - 4.4
• WVGA (800 × 480) resolution or higher
• GPS function

(*)Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

Earth resistance Auto range 20.00/200.00/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Communication Interface Bluetooth Ver2.1 + EDR Class2
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx.Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories LR6 x 4, Instruction manual
8304 (Resister for operation check)
9167 (Carrying case[Hard])

Jual Earth Clamp Testers MODEL 4200

 

Earth Clamp Testers

MODEL 4200

MODEL 4200
CE
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2

Note:
A single earthing can not be measured. (Only for Multiple Earthing System)
  • TRUE RMS φ32 Backlight

Earth resistance Auto range 20.00/200.0/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)*
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.12 hours (when R6 is used)
Approx.24 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx. Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories R6 x 4, Instruction manual
8304 (Resister for operation check)
9166 (Carrying case[Hard])

Jual Earth Resistance & Resistivity Tester KEW 4106

 

Earth Resistance & Resistivity Tester

KEW 4106

KEW 4106
CE
Earth Resistance & Resistivity Tester
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
  • Backlight
 
FunctionRangeResolutionMeasuring rangeAccuracy
Earth resistance
Re
(Rg at
ρ measurement)
2Ω 0.001Ω 0.03 - 2.099Ω ±2%rdg±0.03Ω
20Ω 0.01Ω 0.03 - 20.99Ω ±2%rdg±5dgt (*1)
200Ω 0.1Ω 0.3 - 209.9Ω
2000Ω 1Ω 3 - 2099Ω
20kΩ 10Ω 0.03k - 20.99kΩ
200kΩ 100Ω 0.3k - 209.9kΩ
Auxiliary earth resistance
Rh, Rs
      8% of Re+Rh+Rs
Earth resistivity
ρ
2Ω 0.1Ω·mm - 1Ω·m
Autoranging
0.2 - 395.6Ω·m ρ=2×π×a×Rg (*2)
20Ω 0.2 - 3956Ω·m
200Ω 20 - 39.56kΩ·m
2000Ω 0.2 - 395.6kΩ·m
20kΩ 2.0 - 1999kΩ·m
200kΩ
Series interference voltage
Ust (A.C only) (*3)
50V 0.1V 0 - 50.9Vrms ±2%rdg±2dgt (50/60Hz)
±3%rdg±2dgt (40 - 500Hz)
Frequency
Fst
Autoranging 0.1Hz
1Hz
40Hz - 500Hz ±1%rdg±2dgt
Measuring method Earth resistance: Fall-of-potential method
(currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage)
RMS Rectifier (between the E-S Terminals)
Memory capacity 800 data
Communication Interface Model 8212-USB Optical Adaptor
LCD Dot-matrix 192×64 monochrome
Over-range Indication "OL"
Overload Protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Applicable standards IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source DC12V : sizeAA manganese dry battery (R6) × 8
(Auto power off: approx. 5 minutes)
Dimensions 167(L) × 185(W) × 89(D) mm
Weight approx. 900g (including batteries)
Accessories 7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6 × 8, Instruction manual, Calibration certificate
Optional 8212-RS232C (RS232C adaptor with "KEW Report(Software)")

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 25 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...